[ Identification | Description | Input parameters | Links ]

The ILL_IN6 Instrument

The IN6 Time-of-Flight simulation at the ILL (instrument only).

Identification

Description

IN6 is a time focussing time-of-flight spectrometer designed for quasielastic and
inelastic scattering for incident wavelengths in the range of 4 to 6 Angs.

An intense beam is extracted from the H15 guide by a vertically focussing
monochromator array. It consists of three composite pyrolytic graphite
monochromators using the full height (20 cm) of the guide and focussing the beam
at the sample position. In order to minimise the interference with the
subsequent instruments, the monochromator can deliver only four wavelengths:
4.1; 4.6; 5.1; and 5.9 Angs. The second order reflection from the graphite
monochromator is removed by a beryllium-filter cooled at liquid nitrogen
temperature.
To achieve the time-focussing condition, the beam is pulsed by a Fermi chopper.
It has a small slot length to ensure a good transmission. The normal distance
between the Fermi chopper and the sample is 38 cm. To prevent frame-overlap when
the chopper is rotating faster than 7500 rpm, a suppressor chopper is placed
before the Fermi chopper and rotates in phase with the latter.

The secondary spectrometer consists first of an evacuated sample area. The
detector bank is entirely covered with detector boxes, thus avoiding the
inconvenience of moving the counters.

This instrument model contains a cold source a triple monochromator
(using the GROUP), two Fermi Choppers (including one background chopper), a
liquid sample handling coherent and incoherent processes (elastic and inelastic)
with multiple scattering, customized monitors, and the SPLIT mechanism to
improve the statistics. The H15 guide is not described in this model.

Input parameters

Parameters in boldface are required; the others are optional.
NameUnitDescriptionDefault
lambdaAngswavelength within 4.14|4.6|5.12|5.924.14
dlambdaAngswavelength HALF spread. default is 0.0750.075
SPEEDrpmFermi chopper speed. -1=auto, 0=stopped in open pos.-1
M1coder valuesmonochromator motor 1 position. -1=auto-1
M2coder valuesmonochromator motor 2 positinn. -1=auto-1
M3coder valuesmonochromator motor 3 position. -1=auto-1
MONITORsomething like time in smonitor preset1
CHA_WIDTHuschannel width. -1=auto-1
TOF_DELAYusTOF delay. -1=auto-1
TOF_CHA_RESOL1number of channels.128
ELPEAK1elastic peak channel. -1=auto-1
RATIO1Suppressor speed ratio. -1=no suppressor.1
mFC1super mirror FermiChopper coating m-value0
PHASEdegFermi phase w/r/ to Suppressor. -360=auto-360
Sqw_cohstrsample coherent S(q,w) file name"Rb_liq_coh.sqw"
Sqw_incstrsample incoherent S(q,w) file name"Rb_liq_inc.sqw"
radiusmouter radius of sample hollow cylinder0.01
thicknessmthickness of sample hollow cylinder0.005