loading system configuration loading override configuration from /users/willend/McCode/tools/Python/mctest/../mccodelib/mcstas-test/McStas_DUAL_A100_DMSC/mccode_config.json INFO: Using directory: "1" INFO: Using existing c-file: ./PSI_Focus.c INFO: Using existing binary: ./PSI_Focus.out INFO: === -------------------------------------------------------------------------- WARNING: No preset parameters were found for the device that Open MPI detected: Local host: r6n22 Device name: mlx5_0 Device vendor ID: 0x02c9 Device vendor part ID: 4123 Default device parameters will be used, which may result in lower performance. You can edit any of the files specified by the btl_openib_device_param_files MCA parameter to set values for your device. NOTE: You can turn off this warning by setting the MCA parameter btl_openib_warn_no_device_params_found to 0. -------------------------------------------------------------------------- Simulation 'PSI_Focus' (/users/willend/TESTS/2023-03-01/McStas_DUAL_A100_DMSC_5e7/PSI_Focus/PSI_Focus.instr): running on 2 nodes (master is 'r6n22.esss.dk', MPI version 3.1). Have found 2 GPU devices on rank 1. Will use device 1. Have found 2 GPU devices on rank 0. Will use device 0. [PSI_Focus] Initialize [PSI_Focus] Initialize DiskChopper: FirstChopper WARNING: chopper will NOT absorb neutrons outside radius 0.7 [m] DiskChopper: FirstChopper: frequency=23.1251 [Hz] 1387.5 [rpm], time frame=0.0216215 [s] phase=28.2335 [deg] 2 slits, angle=11.4783 [deg] height=0.7 [m], width=0.07 [m] at radius=0.35 [m] DiskChopper: FirstChopper WARNING: chopper will NOT absorb neutrons outside radius 0.7 [m] DiskChopper: FirstChopper: frequency=23.1251 [Hz] 1387.5 [rpm], time frame=0.0216215 [s] phase=28.2335 [deg] 2 slits, angle=11.4783 [deg] height=0.7 [m], width=0.07 [m] at radius=0.35 [m] Table from file '' (catenated) is empty. Table from file '' (catenated) is empty. Incoherent: Sample: Vc=13.827 [Angs] sigma_abs=5.08 [barn] sigma_inc=5.08 [barn] *** TRACE end *** Save [PSI_Focus] Detector: lambdaGuideExit_I=4.34549e+09 lambdaGuideExit_ERR=1.93787e+06 lambdaGuideExit_N=1.87153e+07 "lambdaguide.dat" Detector: DivMonGuideExit_I=4.34494e+09 DivMonGuideExit_ERR=1.93777e+06 DivMonGuideExit_N=1.87102e+07 "divguide.dat" Detector: PSDGuideExit_I=4.3444e+09 PSDGuideExit_ERR=1.93766e+06 PSDGuideExit_N=1.87053e+07 "psdguide.dat" Detector: PSDmon1Chopper_I=2.6755e+08 PSDmon1Chopper_ERR=120535 PSDmon1Chopper_N=1.84224e+07 "psdchopper.dat" Detector: PSDmonMono_I=2.66977e+08 PSDmonMono_ERR=120500 PSDmonMono_N=1.5634e+07 "psdmono.dat" Detector: DivMonMono_I=2.66932e+08 DivMonMono_ERR=120497 DivMonMono_N=1.55724e+07 "divmono.dat" Detector: lambdaFermi_I=1.53846e+07 lambdaFermi_ERR=7767.74 lambdaFermi_N=2.75199e+07 "lambdafermi.dat" Detector: EMON_Fermi_I=1.45207e+07 EMON_Fermi_ERR=7692.93 EMON_Fermi_N=1.53881e+07 "emon_fermi.dat" : 6.75637 meV , E-width : -nan meV : 6.9466 meV , E-width : -nan meV Detector: DivMonfermi1_I=1.3366e+07 DivMonfermi1_ERR=7462.84 DivMonfermi1_N=9.64938e+06 "divfermi1.dat" Detector: PSD_Fermi1_I=1.45233e+07 PSD_Fermi1_ERR=7693.37 PSD_Fermi1_N=1.60376e+07 "psdfermi1.dat" Detector: PSD_Fermi2_I=445937 PSD_Fermi2_ERR=1327.99 PSD_Fermi2_N=455120 "psdfermi2.dat" Detector: DivMonfermi2_I=412860 DivMonfermi2_ERR=1290.38 DivMonfermi2_N=302062 "divfermi2.dat" Detector: PSD_SAMPLE_I=163886 PSD_SAMPLE_ERR=895.757 PSD_SAMPLE_N=67777 "psdsample.dat" Detector: DivMon_Sample_I=91247.1 DivMon_Sample_ERR=677.928 DivMon_Sample_N=37143 "div2.dat" : 7.07699 meV , E-width : 0.124557 meV Detector: EMON_SAMPLE_I=91265.5 EMON_SAMPLE_ERR=677.99 EMON_SAMPLE_N=37146 "emon_sample.dat" : 7.06934 meV , E-width : 0.030193 meV : 7.24214 meV , E-width : -nan meV Finally [PSI_Focus: 1]. Time: 2 [s] Detector: EMON_DET_I=57674 EMON_DET_ERR=160.348 EMON_DET_N=431279 "emon_det.dat" : 7.29617 meV , E-width : -nan meV Finally [PSI_Focus: 1]. Time: 2 [s] [r6n22.esss.dk:1574059] 1 more process has sent help message help-mpi-btl-openib.txt / no device params found [r6n22.esss.dk:1574059] Set MCA parameter "orte_base_help_aggregate" to 0 to see all help / error messages INFO: Placing instr file copy /users/willend/TESTS/2023-03-01/McStas_DUAL_A100_DMSC_5e7/PSI_Focus/PSI_Focus.instr in dataset 1