loading system configuration loading user configuration from /users/willend/.mcstas/3.x-dev/mccode_config.json loading override configuration from /users/willend/McCode/tools/Python/mctest/../mccodelib/mcstas-test/McStas_DUAL_A100_DMSC/mccode_config.json INFO: Using directory: "1" INFO: Using existing c-file: ./Test_Sqw.c INFO: Using existing binary: ./Test_Sqw.out INFO: === -------------------------------------------------------------------------- WARNING: No preset parameters were found for the device that Open MPI detected: Local host: r6n22 Device name: mlx5_0 Device vendor ID: 0x02c9 Device vendor part ID: 4123 Default device parameters will be used, which may result in lower performance. You can edit any of the files specified by the btl_openib_device_param_files MCA parameter to set values for your device. NOTE: You can turn off this warning by setting the MCA parameter btl_openib_warn_no_device_params_found to 0. -------------------------------------------------------------------------- Simulation 'Test_Sqw' (/users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Sqw/Test_Sqw.instr): running on 2 nodes (master is 'r6n22.esss.dk', MPI version 3.1). Have found 2 GPU devices on rank 1. Will use device 1. Have found 2 GPU devices on rank 0. Will use device 0. [Test_Sqw] Initialize [Test_Sqw] Initialize Isotropic_Sqw: Sqw: is a cylinder: radius=0.005000 thickness=0.000000 height=0.100000 [J Comp Phys 228 (2009) 5251] Opening input file '/users/willend/McStas/mcstas/3.x-dev/tools/Python/mcrun/../mccodelib/../../../data/Rb_liq_tot.sqw' (Table_Read_Offset) Opening input file '/users/willend/McStas/mcstas/3.x-dev/tools/Python/mcrun/../mccodelib/../../../data/Rb_liq_tot.sqw' (Table_Read_Offset) Opening input file '/users/willend/McStas/mcstas/3.x-dev/tools/Python/mcrun/../mccodelib/../../../data/Rb_liq_tot.sqw' (Table_Read_Offset) Opening input file '/users/willend/McStas/mcstas/3.x-dev/tools/Python/mcrun/../mccodelib/../../../data/Rb_liq_tot.sqw' (Table_Read_Offset) Isotropic_Sqw: Sqw: Temperature set to T=350 [K] Isotropic_Sqw: Sqw: S(q,w) data from Rb_liq_tot.sqw (coh) assumed to be classical (symmetrised in energy). Isotropic_Sqw: Sqw: Applying exp(hw/2kT) factor with T=350 [K] on Rb_liq_tot.sqw file (classical/symmetric) using 'Frommhold' quantum correction Isotropic_Sqw: Sqw: Generated Rb_liq_tot.sqw coherent Sqw q=[0.3:5.5 Angs-1] w=[0:21.7725 meV] |S|=0.237096 size=[105x199] sigma=6.32 [barns] normalization factor S(q,w)*0.114853 (auto) \int q^2 S(q) dq=481.095 Isotropic_Sqw: Sqw: Using Isotropic elastic incoherent scattering (sigma=0.5 [barns]) *** TRACE end *** Save [Test_Sqw] Detector: Sph_mon_I=1.21352e+08 Sph_mon_ERR=111871 Sph_mon_N=1.17681e+06 "Sphere.dat" Finally [Test_Sqw: 1]. Time: 1 [s] Finally [Test_Sqw: 1]. Time: 1 [s] Isotropic_Sqw: Sqw: Scattering fraction=0.0235364 of incoming intensity Absorption fraction =0.07187 Single scattering intensity =1.49581e+07 (coh=4.38622e+06 inc=1.05719e+07) Multiple scattering intensity =1.52137e+06 [r6n22.esss.dk:4151178] 1 more process has sent help message help-mpi-btl-openib.txt / no device params found [r6n22.esss.dk:4151178] Set MCA parameter "orte_base_help_aggregate" to 0 to see all help / error messages INFO: Placing instr file copy /users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Sqw/Test_Sqw.instr in dataset 1