loading system configuration loading user configuration from /users/willend/.mcstas/3.x-dev/mccode_config.json loading override configuration from /users/willend/McCode/tools/Python/mctest/../mccodelib/mcstas-test/McStas_DUAL_A100_DMSC/mccode_config.json INFO: Using directory: "4" INFO: Using existing c-file: ./Test_Sources.c INFO: Using existing binary: ./Test_Sources.out INFO: === -------------------------------------------------------------------------- WARNING: No preset parameters were found for the device that Open MPI detected: Local host: r6n22 Device name: mlx5_0 Device vendor ID: 0x02c9 Device vendor part ID: 4123 Default device parameters will be used, which may result in lower performance. You can edit any of the files specified by the btl_openib_device_param_files MCA parameter to set values for your device. NOTE: You can turn off this warning by setting the MCA parameter btl_openib_warn_no_device_params_found to 0. -------------------------------------------------------------------------- Simulation 'Test_Sources' (/users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Sources/Test_Sources.instr): running on 2 nodes (master is 'r6n22.esss.dk', MPI version 3.1). Have found 2 GPU devices on rank 1. Will use device 1. Have found 2 GPU devices on rank 0. Will use device 0. Test_Sources: Using Source_gen Studied wavelength range is [1 11] AA [Test_Sources] Initialize sa7: Setting up for sector W, beamline 8, global orientation angle is 108.7, internal angle 15 sa7: Focusing at rectagle sized 0.1 x 0.1 - positioned at location (x,y,z)=(0 m, 0 m, 1 m) ( from dist parameter -> distance 1 ) sa7: Cold and Thermal brilliance performance multiplicators are c_performance=1 and t_performance=1 sa7: NOT using time focusing Test_Sources: Using Source_gen Studied wavelength range is [1 11] AA [Test_Sources] Initialize Source_gen: component sa5 (square 0.01 x 0.01) focusing distance dist=1 area=0.1 x 0.1 spectra 1.000 to 11.000 AA (0.676 to 81.810 meV) T1=216.8 K (2.093 AA), T2=33.9 K (5.292 AA), T3=16.7 K (7.539 AA) Flux is dPhi/dlambda in [n/s/cm2]. sa7: Setting up for sector W, beamline 8, global orientation angle is 108.7, internal angle 15 sa7: Focusing at rectagle sized 0.1 x 0.1 - positioned at location (x,y,z)=(0 m, 0 m, 1 m) ( from dist parameter -> distance 1 ) sa7: Cold and Thermal brilliance performance multiplicators are c_performance=1 and t_performance=1 sa7: NOT using time focusing *** TRACE end *** Storing event logfile --> 4/Events_1.log Save [Test_Sources] Storing event logfile --> 4/Events_0.log Done storing logfile. Done storing logfile. Detector: m1_I=2.42312e+11 m1_ERR=4.81393e+07 m1_N=5e+07 "m1_1667267506.L" Detector: m2_I=2.42312e+11 m2_ERR=4.81393e+07 m2_N=5e+07 "m2_1667267506.x_y" Detector: m3_I=2.42312e+11 m3_ERR=4.81393e+07 m3_N=5e+07 "m3_1667267506.hd_vd" Finally [Test_Sources: 4]. Time: 0 [s] Finally [Test_Sources: 4]. Time: 0 [s] [r6n22.esss.dk:4150887] 1 more process has sent help message help-mpi-btl-openib.txt / no device params found [r6n22.esss.dk:4150887] Set MCA parameter "orte_base_help_aggregate" to 0 to see all help / error messages INFO: Placing instr file copy /users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Sources/Test_Sources.instr in dataset 4