loading system configuration loading user configuration from /users/willend/.mcstas/3.x-dev/mccode_config.json loading override configuration from /users/willend/McCode/tools/Python/mctest/../mccodelib/mcstas-test/McStas_DUAL_A100_DMSC/mccode_config.json INFO: Using directory: "1" INFO: Using existing c-file: ./Test_Pol_Bender.c INFO: Using existing binary: ./Test_Pol_Bender.out INFO: === -------------------------------------------------------------------------- WARNING: No preset parameters were found for the device that Open MPI detected: Local host: r6n22 Device name: mlx5_0 Device vendor ID: 0x02c9 Device vendor part ID: 4123 Default device parameters will be used, which may result in lower performance. You can edit any of the files specified by the btl_openib_device_param_files MCA parameter to set values for your device. NOTE: You can turn off this warning by setting the MCA parameter btl_openib_warn_no_device_params_found to 0. -------------------------------------------------------------------------- Simulation 'Test_Pol_Bender' (/users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Pol_Bender/Test_Pol_Bender.instr): running on 2 nodes (master is 'r6n22.esss.dk', MPI version 3.1). Have found 2 GPU devices on rank 0. Will use device 0. Have found 2 GPU devices on rank 1. Will use device 1. [Test_Pol_Bender] Initialize [Test_Pol_Bender] Initialize *** TRACE end *** Save [Test_Pol_Bender] Detector: lamStart_I=1.61682 lamStart_ERR=0.000228653 lamStart_N=5e+07 "lambdaStart.dat" Detector: psdStart_I=1.61682 psdStart_ERR=0.000228653 psdStart_N=5e+07 "psdStart.dat" Detector: lamStopBender_I=0.654681 lamStopBender_ERR=0.000139814 lamStopBender_N=2.72574e+07 "lambdaStopBender.dat" Detector: psdBender_I=0.654681 psdBender_ERR=0.000139814 psdBender_N=2.72574e+07 "psdBender.dat" Detector: pollambdaMonitorY_I=0.654681 pollambdaMonitorY_ERR=0.000139814 pollambdaMonitorY_N=2.72574e+07 "pollambdaMonY.data" Detector: meanpollambdaMonitorY_I=0.330791 meanpollambdaMonitorY_ERR=0.0014661 meanpollambdaMonitorY_N=2.72574e+07 "meanpollambdaMonY.data" Finally [Test_Pol_Bender: 1]. Time: 0 [s] Finally [Test_Pol_Bender: 1]. Time: 0 [s] [r6n22.esss.dk:4145645] 1 more process has sent help message help-mpi-btl-openib.txt / no device params found [r6n22.esss.dk:4145645] Set MCA parameter "orte_base_help_aggregate" to 0 to see all help / error messages INFO: Placing instr file copy /users/willend/TESTS/2022-11-01/McStas_DUAL_A100_DMSC_5e7/Test_Pol_Bender/Test_Pol_Bender.instr in dataset 1