loading system configuration Using all default parameter values INFO: Using directory: "display" INFO: Using existing c-file: RITA-II.c INFO: Using existing binary: RITA-II.exe INFO: === RITA_II WARNING: Neither EI, EF nor EN defined: Energies are set from user angle input: RITA_II: WARNING: EI has been adjusted to inf[meV] (A2 = 0[deg]) RITA_II: WARNING: EF has been adjusted to inf[meV] (A6 = 0[deg]) RITA_II: Running in HKL mode RITA_II: ERROR: Q modulus too big. Can not close triangle. arg=-nan(ind) [qhkl2angles] INFO: call to RITA-II.exe failed with Command 'RITA-II.exe --trace=1 --ncount=0.0 --dir=display --format=McCode --bufsiz=10000000 --no-output-files --yes' returned non-zero exit status 87. Traceback (most recent call last): File "C:\Users\runneradmin\micromamba\envs\mcstas\bin\\..\share\mcstas\tools\Python\mcrun\mcrun.py", line 685, in main() ~~~~^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\bin\\..\share\mcstas\tools\Python\mcrun\mcrun.py", line 657, in main mcstas.run() # in mccode.py ~~~~~~~~~~^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mcrun\mccode.py", line 406, in run return self.runMPI(args, pipe, override_mpi) ~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mcrun\mccode.py", line 461, in runMPI return Process(binpath).run(args, pipe=pipe) ~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mcrun\mccode.py", line 78, in run raise err File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mcrun\mccode.py", line 74, in run proc = run(command, shell=True, check=True, text=True, capture_output=pipe) File "C:\Users\runneradmin\micromamba\envs\mcstas\Lib\subprocess.py", line 578, in run raise CalledProcessError(retcode, process.args, output=stdout, stderr=stderr) subprocess.CalledProcessError: Command 'RITA-II.exe --trace=1 --ncount=0.0 --dir=display --format=McCode --bufsiz=10000000 --no-output-files --yes' returned non-zero exit status 87. Using all default parameter values Source wavelength interval=3.924 - 4.166[Ang] Source energy interval=4.713 - 5.314[meV] Detector energy interval=0 - 0[meV] * GUIDE MIRROR ALPHA=0 [AA] * MONOCHROMATOR IS FLAT: RV=1.54 RITA_II: Detailed TAS configuration * Incoming beam: EI=inf [meV] KI=inf [Angs-1] Vi=inf [m/s] * Outgoing beam: EF=inf [meV] KF=inf [Angs-1] Vf=inf [m/s] (RITA Analyzer Angle between blades: DA4=0.9092[deg]) Traceback (most recent call last): File "C:\Users\runneradmin\micromamba\envs\mcstas\bin\\..\share\mcstas\tools\Python\mcdisplay\webgl-classic\mcdisplay.py", line 203, in main(**args) ~~~~^^^^^^^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\bin\\..\share\mcstas\tools\Python\mcdisplay\webgl-classic\mcdisplay.py", line 170, in main instrument = reader.read_instrument() File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mccodelib\mcdisplayutils.py", line 46, in read_instrument self.pipeman.join() ~~~~~~~~~~~~~~~~~^^ File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mccodelib\pipetools.py", line 345, in join raise self.reader.exc_obj File "C:\Users\runneradmin\micromamba\envs\mcstas\share\mcstas\tools\Python\mccodelib\pipetools.py", line 284, in run raise Exception("TraceReader - mcrun process exited with code: %s" % str(poll)) Exception: TraceReader - mcrun process exited with code: 1